Practical application of active premagnetization in transformerless DC/DC converters
Zusammenfassung
Magnetic devices are used in almost every power electronic system. Therefore, their purpose and with that their requirements can vary in a wide range. The consequence is a large number of options regarding the priority of optimisation. In this work, the focus is on reducing the volume or weight of inductors in transformerless DC-DC converters. Active prmeagnetization is choosed as an optimisation approach. The technique enables an operation of the DC-DC-converter in the Triangular Current Mode (TCM), whereby switching-on-losses and recovery losses can be reduced or even eliminated. In a first step the basic methods of active premagnetization are analysed. For each one of them, a state of the art is presented. The focus of the following investigations lies on mixed premagnetization and orthogonal premagnetization. For both premagnetization methods basic investigations are conducted regarding the impact of the number of turns of the auxiliary winding, its arrangement and the direction of the auxiliary current on the magnetic device. The results show a signifficant impact of the direction of the auxiliary current. The other investigated factors are insignificant. Finally, the usage of a premagnetizable inductor in a full bridge converter and a half bridge converter is investigated at different voltage levels. The active premagnetization can cause a significant reduction of the inductor's volume. In case of lower voltage levels the overall effeciency of the circuit decreases. Regarding higher voltage levels the active premagnetization causes a higher overall efficiency, especially at partical load conditions bcompared to a conventional inductor. However, a higher effort regarding the generation of the auxiliary current and its control has to be considered.
Verweisung auf anderssprachige Version
🇩🇪 ger (ISO-639-2/B)Zitieren
@phdthesis{doi:10.17170/kobra-202211117096,
author={Pfeiffer, Jonas},
title={Practical application of active premagnetization in transformerless DC/DC converters},
school={Kassel, Universität Kassel, Fachbereich Elektrotechnik / Informatik},
month={05},
year={2023}
}
0500 Oax 0501 Text $btxt$2rdacontent 0502 Computermedien $bc$2rdacarrier 1100 2023$n2023 1500 1/eng 2050 ##0##http://hdl.handle.net/123456789/14737 3000 Pfeiffer, Jonas 4000 Practical application of active premagnetization in transformerless DC/DC converters / Pfeiffer, Jonas 4030 4060 Online-Ressource 4085 ##0##=u http://nbn-resolving.de/http://hdl.handle.net/123456789/14737=x R 4204 \$dDissertation 4170 5550 {{Konverter <Elektronik>}} 5550 {{Gleichspannungswandler}} 5550 {{Vormagnetisierung}} 5550 {{Magnetisches Bauelement}} 5550 {{Induktivität}} 7136 ##0##http://hdl.handle.net/123456789/14737
2023-05-22T14:26:11Z 2023-05-22T14:26:11Z 2023-05-17 doi:10.17170/kobra-202211117096 http://hdl.handle.net/123456789/14737 eng Namensnennung - Weitergabe unter gleichen Bedingungen 4.0 International http://creativecommons.org/licenses/by-sa/4.0/ 620 Practical application of active premagnetization in transformerless DC/DC converters Dissertation Magnetic devices are used in almost every power electronic system. Therefore, their purpose and with that their requirements can vary in a wide range. The consequence is a large number of options regarding the priority of optimisation. In this work, the focus is on reducing the volume or weight of inductors in transformerless DC-DC converters. Active prmeagnetization is choosed as an optimisation approach. The technique enables an operation of the DC-DC-converter in the Triangular Current Mode (TCM), whereby switching-on-losses and recovery losses can be reduced or even eliminated. In a first step the basic methods of active premagnetization are analysed. For each one of them, a state of the art is presented. The focus of the following investigations lies on mixed premagnetization and orthogonal premagnetization. For both premagnetization methods basic investigations are conducted regarding the impact of the number of turns of the auxiliary winding, its arrangement and the direction of the auxiliary current on the magnetic device. The results show a signifficant impact of the direction of the auxiliary current. The other investigated factors are insignificant. Finally, the usage of a premagnetizable inductor in a full bridge converter and a half bridge converter is investigated at different voltage levels. The active premagnetization can cause a significant reduction of the inductor's volume. In case of lower voltage levels the overall effeciency of the circuit decreases. Regarding higher voltage levels the active premagnetization causes a higher overall efficiency, especially at partical load conditions bcompared to a conventional inductor. However, a higher effort regarding the generation of the auxiliary current and its control has to be considered. open access Pfeiffer, Jonas 2022-07-18 XX, 157, XXI-LI Seiten Kassel, Universität Kassel, Fachbereich Elektrotechnik / Informatik Zacharias, Peter (Prof. Dr.) Friebe, Jens (Prof. Dr.) Konverter <Elektronik> Gleichspannungswandler Vormagnetisierung Magnetisches Bauelement Induktivität publishedVersion false doi:10.17170/kobra-202211117095
Die folgenden Lizenzbestimmungen sind mit dieser Ressource verbunden: