Show simple item record

dc.date.accessioned2024-07-18T12:24:27Z
dc.date.available2024-07-18T12:24:27Z
dc.date.issued2024
dc.identifierdoi:10.17170/kobra-2024071610531
dc.identifier.urihttp://hdl.handle.net/123456789/15924
dc.language.isoger
dc.subjectLFSM-Ueng
dc.subjectdispensability-orientedeng
dc.subjectswitching loadseng
dc.subjectrandomized frequency thresholdseng
dc.subjectfrequency-dependent consumptioneng
dc.subjectunderfrequency load sheddingeng
dc.subjectentbehrlichkeitsorientiertger
dc.subjectschaltende Lastenger
dc.subjectzufällig gewählte Frequenzschwellenger
dc.subjectfrequenzabhängiger Verbrauchger
dc.subjectUnterfrequenzlastabwurfger
dc.subject.ddc620
dc.titleUntersuchung der netzseitigen Machbarkeit einer entbehrlichkeitsorientierten Einbindung von Lasten in LFSM-Uger
dc.typeMasterarbeit
dcterms.abstractIn der vorliegenden Arbeit werden die Machbarkeit und frequenzstabilisierenden Eigenschaften einer Implementierung von lastseitigem “Limited Frequency Sensitive Mode - Underfrequency” (LFSM-U) in Stromnetzen untersucht. Der Fokus der Untersuchung liegt auf dem aggregierten Verhalten vieler Lasten anstelle einzelner Lasten. Grundlegende Eigenschaften verschiedener Arten von Lasten, die an LFSMU teilnehmen, wurden definiert. Ein stochastischer Ansatz wurde entwickelt, um das aggregierte LFSM-U-Verhalten vieler nicht regelbarer Lasten darzustellen, die nur geschaltet werden können. Ein Matlab-Simulink-Modell des IEEE 14-Bus-Netzwerks wurde entwickelt, um kritische Netzsituationen zu simulieren. Das Hauptziel der Studie war es, die frequenzstabilisierenden Effekte des lastseitigen LFSM-U zu demonstrieren und die Auswirkungen verschiedener Einflussfaktoren wie des Anteils an LFSM-U-fähigen Lasten, Schaltverzögerungen oder stark unterschiedlicher Anteile von Lasten mit verschiedenem LFSM-U-Verhalten zu bewerten. Die Ergebnisse zeigen, dass ein Netzwerk mit erheblichem Anteil an LFSM-U-fähigen Lasten Unterfrequenzlastabwurfe während kritischer Situationen vermeiden oder abschwächen und die Netzstabilität aufrechterhalten kann. Allerdings führte eine umfangreiche Beteiligung von LFSM-U zu mäßigem bis starkem Einschwingverhalten bei Frequenz und Leistung, das auch unter extremen Bedingungen ausreichend gedämpft blieb.ger
dcterms.abstractThis thesis investigates the feasibility and frequency-stabilizing properties of implementing load-side ‘Limited Frequency Sensitive Mode - Underfrequency’ (LFSM-U) in power grids. The research focuses on the aggregated behavior of multiple loads rather than individual ones. Basic characteristics of different kinds of loads participating in LFSM-U have been defined. A stochastic approach was developed to represent the aggregated LFSM-U behavior of many non-controllable loads that can only be switched. A Matlab-Simulink model of the IEEE 14-bus network was developed to simulate critical network situations. The study’s primary goal was to demonstrate the frequency-stabilizing effects of load-side LFSM-U and assess the impacts of different influencing factors such as LFSM-U penetration, delay times, or largely different shares of loads with differing LFSM-U behaviour. Results indicate that a network with substantial penetration of LFSM-U capable loads can avoid or mitigate underfrequency load shedding during critical situations and maintain grid stability. However, extensive LFSM-U involvement led to moderate to strong transient oscillations in frequency and power, which remained adequately damped even under extreme conditions.eng
dcterms.accessRightsopen access
dcterms.alternativeInvestigation of the Grid-Side Feasibility of a Dispensability-Oriented Inclusion of Loads in LFSM-Ueng
dcterms.creatorStaude, Jakob Ferdinand
dcterms.dateAccepted2024-06-18
dcterms.extent77 Seiten
dc.contributor.corporatenameKassel, Universität Kassel, Fachbereich Maschinenbauger
dc.contributor.refereeBraun, Martin (Prof. Dr.)
dc.contributor.refereeHoffmann, Clemens (Prof. Dr.)
dc.contributor.refereeSchittek, Walter
dc.relation.projectidPtJ FKZ: 0350048D
dc.subject.swdElektrizitätsversorgungsnetzger
dc.subject.swdFrequenzstabilitätger
dc.subject.swdLastabwurf <Energietechnik>ger
dc.type.versionpublishedVersion
kup.iskupfalse