Comparison Between Two Hydrodynamic Models in Simulating Physical Processes of a Reservoir with Complex Morphology: Maroon Reservoir

dc.date.accessioned2020-05-22T09:32:20Z
dc.date.available2020-05-22T09:32:20Z
dc.date.issued2020-03-14
dc.description.sponsorshipGefördert durch den Publikationsfonds der Universität Kassel
dc.identifierdoi:10.17170/kobra-202005201280
dc.identifier.urihttp://hdl.handle.net/123456789/11567
dc.language.isoeng
dc.relation.doidoi:10.3390/w12030814
dc.rightsNamensnennung 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectMaroon Reservoireng
dc.subjectAEM3Deng
dc.subjectMIKE3eng
dc.subjecthydrodynamic modelingeng
dc.subjectmodel intercomparisoneng
dc.subject.ddc550
dc.subject.ddc620
dc.subject.swdHydrodynamikger
dc.subject.swdHydrodynamisches Modellger
dc.subject.swdHydrologieger
dc.titleComparison Between Two Hydrodynamic Models in Simulating Physical Processes of a Reservoir with Complex Morphology: Maroon Reservoireng
dc.typeAufsatz
dc.type.versionpublishedVersion
dcterms.abstractTwo 3D hydrodynamic models, AEM3D and MIKE3, are compared in simulating hydrodynamics of the Maroon Reservoir in southwest Iran. The reservoir has a complex bathymetry with steep walls, which makes it a good case for studying the performance of hydrodynamic models. The models were compared together and with measured water temperatures from different locations of the reservoir in a five-month period between December 2011 and April 2012. The results indicated that the AEM3D model, which uses a finite difference scheme with a purely z-level vertical discretization, showed better consistency with observations so that the AME and RMSE of the model remain below 1 °C. The MIKE3 model showed overall higher errors from 56% to 130% larger than AEM3D and the level of error strongly depends on its vertical discretization method and the turbulence model. The lowest errors by MIKE3 were seen by the k-ε turbulence model with a hybrid z-sigma discretization, while the highest errors were generated by using the sigma vertical discretization. The vertical mixing model in AEM3D model, used instead of the constant eddy viscosity or k-ε formulation, showed a better performance in modeling vertical mixing and wind mixed layer, which is another reason of observing better results by this model than MIKE3. Overall, this study shows AEM3D as a more appropriate model for simulating deep and complex reservoirs with steep slopes and walls.eng
dcterms.accessRightsopen access
dcterms.creatorZamani, Behnam
dcterms.creatorKoch, Manfred
dcterms.source.identifierEISSN 2073-4441
dcterms.source.issueIssue 3
dcterms.source.journalWatereng
dcterms.source.pageinfo814
dcterms.source.volumeVolume 12
kup.iskupfalse

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
water_12_00814.pdf
Size:
7.59 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.03 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections