Energy and Exergy Based Thermal Analysis of a Solar Assisted Yogurt Processing Unit

dc.date.accessioned2022-06-20T09:53:39Z
dc.date.available2022-06-20T09:53:39Z
dc.date.issued2022-06-01
dc.description.sponsorshipGefördert durch den Publikationsfonds der Universität Kasselger
dc.identifierdoi:10.17170/kobra-202206146341
dc.identifier.urihttp://hdl.handle.net/123456789/13927
dc.language.isoengeng
dc.relation.doidoi:10.3389/fenrg.2022.887639
dc.rightsNamensnennung 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectyogurt processingeng
dc.subjectsolar energyeng
dc.subjectenergy and exergyeng
dc.subjectevacuated tube collectoreng
dc.subjectthermal losseseng
dc.subject.ddc333
dc.subject.swdJoghurtherstellungger
dc.subject.swdSonnenenergieger
dc.subject.swdExergieger
dc.subject.swdEnergieger
dc.subject.swdWärmeverlustger
dc.titleEnergy and Exergy Based Thermal Analysis of a Solar Assisted Yogurt Processing Uniteng
dc.typeAufsatz
dc.type.versionpublishedVersion
dcterms.abstractEnergy and exergy based thermal analysis was conducted for a solar assisted yogurt processing unit capable of performing required heating and cooling processes in a single container. The system consisted of a round-shaped fermentation chamber connected with a hot water storage tank coupled with an evacuated tube collector and a pillow plate at the bottom of the chamber for cooling through a PV-operated refrigeration unit. Experiments were conducted using three different volumes of cow’s raw milk (30, 40, and 50 L). Energy analysis showed that 40% of the total energy was consumed during the heating process of raw milk in all cases, with an overall heat transfer efficiency of more than 80%. The specific product energy was calculated to be lower (485 kJ/kg) for the higher volume of milk (50 L). The exergy losses in the compressor of the refrigeration unit were calculated almost constant (1.0037 kW), while the exergy recovered during the refrigeration process was found in the range of 0.48–4.54 kJ/kg, 1.35–3.96 kJ/kg, and 0.84–6.18 kJ/kg for 50, 40, and 30 L of batches, respectively. Out of the total available power (2218 W) at the evacuated tube collector, 69.70% of energy was available for milk heating. The study is useful for designing optimization based on the distribution of energy and losses at various system components.eng
dcterms.accessRightsopen access
dcterms.creatorHusnain, Syed Nabeel
dcterms.creatorAmjad, Waseem
dcterms.creatorMunir, Anjum
dcterms.creatorHensel, Oliver
dcterms.source.articlenumber887639
dcterms.source.identifiereissn:2296-598X
dcterms.source.journalFrontiers in Energy Researcheng
dcterms.source.volumeVolume 10
kup.iskupfalse

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
fenrg_10_887639.pdf
Size:
2.39 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.03 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections