Anmeldung z.Z. nicht möglich
Login not possible
 

Total Site Utility Systems Optimisation for Milk Powder Production

dc.date.accessioned2020-12-23T13:32:21Z
dc.date.available2020-12-23T13:32:21Z
dc.date.issued2016
dc.identifierdoi:10.17170/kobra-202012092474
dc.identifier.urihttp://hdl.handle.net/123456789/12375
dc.language.isoengeng
dc.relation.doidoi:10.3303/CET1652040
dc.rightsUrheberrechtlich geschützt
dc.rights.urihttps://rightsstatements.org/page/InC/1.0/
dc.subject.ddc620
dc.subject.swdEnergieeffizienzger
dc.subject.swdTrockenmilchger
dc.subject.swdProduktionssystemger
dc.subject.swdProzessmanagementger
dc.titleTotal Site Utility Systems Optimisation for Milk Powder Productioneng
dc.typeAufsatz
dc.type.versionpublishedVersion
dcterms.abstractThis study applies the Total Site Heat Integration method, in conjunction with a detailed process and utility model, to investigate three methods to increase the energy efficiency of the utility supply system for milk powder production. Sequentially explored opportunities are: (1) increasing boiler efficiency through condensing economisers, (2) waste heat recovery from the chiller unit, and (3) Combined Heat and Power (CHP) for electricity production. The basis for the analysis is the anticipated future milk powder process design, which incorporates results from recent studies that have focused on improving the process design and integration of the heat treatment and evaporator systems and recovering heat from the spray dryer exhaust, which show a combined specific fuel consumption reduction of 29.6 % and a relatively small increase in electricity use of 4.5 %. To maximise boiler efficiency, the study concludes that a condensing economiser for the flue gas can be indirectly matched with heating fluidised bed air flows through the boiler condensate system, which results in specific fuel use reduction of 227 MJ/tp. Chiller waste heat can be upgraded and integrated as a heat source to replace the equivalent specific fuel use of 101 MJ/tp through integration with the site low temperature hot water loop. By designing the steam system to maximise electricity generation in a new turbine, results show that 51 % of the site’s electricity demand may be satisfied by CHP. The combined effect of implementing these three utility systems opportunities is a specific fuel use of 3,868 MJ/tp, of which 530 MJ/tp result from electricity production, and a specific grid electricity demand of 113.4 kWh/tp.eng
dcterms.accessRightsopen access
dcterms.creatorWalmsley, Timothy Gordon
dcterms.creatorAtkins, Martin John
dcterms.creatorWalmsley, Michael R. W.
dcterms.creatorNeale, James R.
dcterms.creatorPhilipp, Matthias
dcterms.creatorSchumm, Gregor
dcterms.creatorPeesel, Ron-Hendrik
dcterms.source.identifierEISSN 2283-9216
dcterms.source.journalChemical engineering transactions (CEt)eng
dcterms.source.pageinfo235-240
dcterms.source.volumeVolume 52
kup.iskupfalse

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
WalmsleyAtkinsWalmsleyNealePhilippSchummPeeselTotal.pdf
Size:
1.16 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.03 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections